Batch Control/Stroke Counter Page 3Batch-sc-rev0611
520-180-000 3/02 Batch Control / Stroke Counter Page 3
Programming for Accuracy
Topresetaccuratebatchprograms,itisimportanttoknowactualsystem
performance.Gatherthisinformationbymeasuringoutputvolumesgener-
atedbytestrunsofthesystems,usingpublishedpumpperformanceas
astartingprogram.Carefulmeasurementwilltellyouhowmuchvolume
yoursystemisactuallydischargingoneverystroke.Youcanthenadjust
theprogramaccordingly.Hereisanexample.
EXAMPLE OF USE:
Aproductisblendedbasedonincomingorders.Twoingredientsare
mixedinaratioof3to1,creatingthenalproduct.
Ordervolumesaretypically50,500,1000,1500and2000gallons.Two
pumpstransfertheingredientstoamixingareafor“batching”.
Pump#1inthisexampleisthetransferpumpforthemainelement.Its
controlhasPresetCountssetasfollows:
Pump#1PresetCounts:......... PO-37.5gallons..... P1-375gallons
................................................ P2-750gallons....... P3-1125gallons.
................................................ P4-1500gallons
StrokeScaleValve:................. 0.34gallonsperstroke
Thecontrol’sStrokeScaleValueissetatthedisplacementperstrokeof
the1½-inchpumptowhichitisconnected,.34gallons.
Pump#2inthisexampleis thetransferpumpfor thesecond element.
ItscontrolhasPresetCountsset
asfollows,basedonthe3to1mixing
ratio:
Pump#2PresetCounts:......... PO-12.5gallons..... P1-125gallons
................................................ P2-250gallons....... P3-375gallons
................................................ P4-500gallons
StrokeScaleValve:................. 0.09gallonsperstroke
Pump#2’scontrolhastheStrokeScaleValuesetatthedisplacement
perstrokeofthe1-inchpumptowhichitisconnected,.09gallons.
Thougheachpumprequiresitsowncontrolunit,bothcontrolscanbe
tiedtogetherwithoneremoteStart/Stopswitchrunningbothunits.
TESTING THE SYSTEM
Sinceeachcontrolgetsonepulseorsignal
from its pump for each stroke, the volumes
referencedintheexampleshouldbesetforthe
closesttotalvolumeavailable.
For example:
Pump#1.............P1-375gallons@
............................0.34gal.perstroke
............................=1102.94strokes
Adjusting for 1103 strokes would deliver
375.02gallons,assuming100%efciencyfrom
pumpandsystem.Realisticexpectationsofa
well-designedandimplementedsystemfallin
therangeof1%to3%.
Basedondataobtainedfromthesystem,
it becomes evident where the system will
perform from an accuracy and efficiency
standpoint.This will indicate adjustments to
bemade.
For example:
Testing showed in the example system
thatPump#1delivered363.93gallons,within
the 3% range of accuracy. Since the Stroke
ScaleValuewassetat.34gallonsperstroke,
1103strokesactuallyproduced.329gallons
perstroke.
Formula is:
Flow÷Strokes=GallonsperStroke
363.93÷ 1103=0.329gal./stroke
This test indicates the system should be
resettoproduceatotalowclosertothebatch
targetof375gallons.
Formula is:
BatchTarget÷Gal.perStroke=#Strokes
 375 ÷0.329=1139.81
Roundedto1140strokes
The controller cannot count a fractional
stroke,sothe numberof strokesis rounded
tothenearestwholenumber,1140.Thisgets
closertothetargetbatchsizeof375gallons,
actuallyproducing375.06gallons.
Thesametypeoftesting,calculationand
adjustmentwouldbeappliedtoallpumpsin
a system. Each pump’s performance will be
effected by the application and system
intotal.
WHERE TO FIND PUBLISHED PUMP
PERFORMANCE
Published pump performance is found on the data sheet
issued for model pump. Displacement is shown to the right
of the performance curve.
If you do not have the appropriate data sheet, contact your
local Warren Rupp or Marathon distributor for a copy. Or
you can contact the Factory Literature Department at the
number shown below.
To receive the correct sheet, be sure to verify the pump
model and type, which is shown on the pump nameplate.